BENVIG HEAT TRANSFER - Our roots are in the Czech Republic, but we work internationally.
phone
Phone
+420 412 590 511
phone
Email
info@benvig.cz

BENVIG HEAT TRANSFER spol. s r.o.

MACHINING CENTRE WITH MOVABLE PORTAL AND FINNING

EXPERTS IN THE FIELD OF OIL, GAS AND POWER INDUSTRY

TURN-KEY DELIVERIES

THE EXPERTS IN HEAT EXCHANGE

Air Cooled Condensers

Electricity production processes result in emissions of low-potential heat into the atmosphere. Air-cooled Condensers (Heat Exchangers) use corrosion-free media at low pressures (water steam, water and glycol mixtures). In many cases cooling of extreme thermal powers is needed. This includes cooling of gas and diesel engines, gas and steam turbines and condensation of the emission steam of steam turbines. More and more, air-cooling replaces water-cooling in power engineering, where it is used a standard as water is rarer in some industrial areas and more expensive. In many areas which require the production of electricity, water sources are lacking and in concentrated industrial areas where water is available, its price is very high.

Download product sheet:

Request more info:

If you would like more information about this product, please fill out the following form and our sales staff will get back to you as soon as possible.

Typical scope of supply, including accessories:

  • ACC (tube bundles and steel structure)
  • Air evacuation system (Steam jet ejectors, water ring vacuum pumps)
  • Condensate tank
  • Condensate pumps
  • Steam duct between TG and ACC
  • Internal piping, including valves
  • Electric supply (switchgears, cables, etc.)
  • I & C system
  • Assembly on Site, commissioning
  • Documentation

Dephlegmator:

During winter period the air-cooled condenser can be operated at a dephlegmator connection if the real steam flow is lower then the safety anti-freezing steam flow. The dephlegmator connection (not included in the scope of supply) in such case will make the continual turbine operation possible without a risk of air-cooled condenser freezing by the condensate. Without a dephlegmator connection it can be operated only with the minimum safety steam flow.

Possible Components:

  • Fan Units
  • Finned Tubes
  • I & C
  • Pre-Assembly
  • Run-Test
  • Steel Structure
  • Tube Bundle
  • Recirculation (winterization)
  • Other Spare Parts

Our products

Czech Republic (Headquarters)

Benvig Heat Transfer spol. s r.o.
Děčínská 288
Benešov nad Ploučnicí, 407 22
Czech Republic

Phone: +420 412 590 511
Phone: +420 412 590 515 (Sales Department)
Phone: +420 412 590 550 (Purchasing Department)
Fax: +420 412 586 360
Email: info@benvig.cz | sales@benvig.cz

IČO: 14867125
DIČ: CZ14867125

Netherlands

Benvig Heat Transfer BV
Smitspol 2
3861 RS Nijkerk
Netherlands

Phone: +31 33 209 16 00
Email: info@benvig.nl